+31 (0) 316 745 745 Monday - Friday 08.00 - 18.00 Typograaf 16 - 6921 VB - Duiven - The Netherlands
Certified
ISO | NSF
Made in NL
LUBRICANT SUPPLIER
Maintain the things
WE VALUE
LOG IN

What is the recommended procedure for using this synthetic fluid to clean a compressor or vacuum pump system, and what are the critical steps involved in the cleaning process?

\

What is the recommended procedure for using this synthetic fluid to clean a compressor or vacuum pump system, and what are the critical steps involved in the cleaning process?

The cleaning procedure using this synthetic fluid involves a series of carefully executed steps to ensure thorough and effective cleaning of the compressor or vacuum pump system. Here is the recommended procedure: For Routine Cleaning: 1. Begin by adding the synthetic fluid directly to the existing oil within the system. The concentration of the synthetic fluid should be determined based on the level of pollution within the system and the intended circulation time. Generally, a concentration between 10% and 20% is suitable. 2. Allow the system to run with the synthetic fluid for a duration of 100 to 150 hours. This extended circulation period ensures that the cleaning action takes place comprehensively. 3. After the circulation period, drain the oil from the system while CLEAN-PLUS COMVAC 32 is still hot. 4. Refill the system with the new compressor or vacuum pump fluid. For Fluid Conversion or Change: 1. To transition from one fluid to another, start by draining the existing fluid completely from the system. 2. Fill the system with 100% of this synthetic fluid (COMP-PLUS Clean). 3. Run the system with the synthetic fluid for a total of 40 hours. During this time, ensure that the fluid circulates effectively. 4. After 40 hours, change the filters within the system. 5. Drain the synthetic cleaner while the system and oil are hot. 6. Next, fill the system with Airtop Clean and circulate CLEAN-PLUS COMVAC 32 for another 40 hours. 7. Drain the Airtop Clean and fill the system with 50% of the new compressor or vacuum pump fluid. 8. Circulate this mixture for 2 hours. 9. Finally, drain the oil from the system while CLEAN-PLUS COMVAC 32 is hot and refill CLEAN-PLUS COMVAC 32 with the new fluid. Following this comprehensive procedure ensures that the compressor or vacuum pump system is thoroughly cleaned and ready for optimal performance, whether for routine maintenance or when transitioning to a different fluid type.

Related keyword: Cleaning procedure

FAQ categories


I like this faq

By continuing to use the site, you agree to the use of cookies. more information

The cookie settings on this website are set to "allow cookies" to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click "Accept" below then you are consenting to this.

Close